Mfc Specified Power Item Reference Description System kW Rating Max PV Input Power Max PV Input Volts Min PV Start Voltage MPPT Input Range
Ginlong Solis 183-1020-100100 2.5kW 3kW 600VDC 50-450VDC
Ginlong Solis 183-1020-100200 Residential grid-tied Photovoltaic (PV) Inverter, NEMA 4X enclosure with natural convection cooling, 3kW, (2) MPPT(s) with operational PV range of 90-520VDC (600VDC PV OCV), (1) inputs per MPPT for connection of up to 2 total PV inputs (3.6kW max combined PV input power), 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz input / 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz sinewave output, 97.1% (CEC) efficiency, each inverter: 13.86"W x 31.89"H x 6.46"D, 33.1 Lbs., Certifications: UL 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 3kW 3.6kW 600VDC 90-520VDC
Ginlong Solis 183-1020-100300 Residential grid-tied Photovoltaic (PV) Inverter, NEMA 4X enclosure with natural convection cooling, 3.6kW, (2) MPPT(s) with operational PV range of 90-520VDC (600VDC PV OCV), (1) inputs per MPPT for connection of up to 2 total PV inputs (4kW max combined PV input power), 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz input / 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz sinewave output, 97.1% (CEC) efficiency, each inverter: 13.86"W x 31.89"H x 6.46"D, 33.1 Lbs., Certifications: UL 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 3.6kW 4kW 600VDC 90-520VDC
Ginlong Solis 183-1020-100400 Residential grid-tied Photovoltaic (PV) Inverter, NEMA 4X enclosure with natural convection cooling, 4kW, (2) MPPT(s) with operational PV range of 90-520VDC (600VDC PV OCV), (1) inputs per MPPT for connection of up to 2 total PV inputs (4.8kW max combined PV input power), 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz input / 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz sinewave output, 97.3% (CEC) efficiency, each inverter: 13.86"W x 31.89"H x 6.46"D, 33.1 Lbs., Certifications: UL 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 4kW 4.8kW 600VDC 90-520VDC
Ginlong Solis 183-1020-100500 Residential grid-tied Photovoltaic (PV) Inverter, NEMA 4X enclosure with natural convection cooling, 4.6kW, (2) MPPT(s) with operational PV range of 90-520VDC (600VDC PV OCV), (1) inputs per MPPT for connection of up to 2 total PV inputs (5.5kW max combined PV input power), 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz input / 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz sinewave output, 97.3% (CEC) efficiency, each inverter: 13.86"W x 31.89"H x 6.46"D, 33.1 Lbs., Certifications: UL 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 4.6kW 5.5kW 600VDC 90-520VDC
Ginlong Solis 183-1020-100600 Residential grid-tied Photovoltaic (PV) Inverter, NEMA 4X enclosure with natural convection cooling, 5kW, (2) MPPT(s) with operational PV range of 90-520VDC (600VDC PV OCV), (1) inputs per MPPT for connection of up to 2 total PV inputs (6kW max combined PV input power), 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz input / 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz sinewave output, 97.3% (CEC) efficiency, each inverter: 13.86"W x 31.89"H x 6.46"D, 33.1 Lbs., Certifications: UL 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 5kW 6kW 600VDC 90-520VDC
Ginlong Solis 183-1020-100700 Residential grid-tied Photovoltaic (PV) Inverter, NEMA 4X enclosure with natural convection cooling, 6kW(240VAC)/5.2kW (208VAC), (2) MPPT(s) with operational PV range of 90-520VDC (600VDC PV OCV), (1) inputs per MPPT for connection of up to 2 total PV inputs (7.2kW max combined PV input power), 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz input / 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz sinewave output, 97.3% (CEC) efficiency, each inverter: 13.86"W x 31.89"H x 6.46"D, 33.1 Lbs., Certifications: UL 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 6kW(240VAC)/5.2kW (208VAC) 7.2kW 600VDC 90-520VDC
Ginlong Solis 183-1020-100800 Residential grid-tied Photovoltaic (PV) Inverter, NEMA 4X enclosure with natural convection cooling, 6kW, (3) MPPT(s) with operational PV range of 100-500VDC (600VDC PV OCV), (1) inputs per MPPT for connection of up to 3 total PV inputs (7.2kW max combined PV input power), 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz input / 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz sinewave output, 97.5% (CEC) efficiency, each inverter: 13.46"W x 28.82"H x 9.8"D, 45.2 Lbs., Certifications: UL 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 6kW 7.2kW 600VDC 100-500VDC
Ginlong Solis 183-1020-100900 Residential grid-tied Photovoltaic (PV) Inverter, NEMA 4X enclosure with natural convection cooling, 7kW, (3) MPPT(s) with operational PV range of 100-500VDC (600VDC PV OCV), (1) inputs per MPPT for connection of up to 3 total PV inputs (8.4kW max combined PV input power), 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz input / 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz sinewave output, 97.5% (CEC) efficiency, each inverter: 13.46"W x 28.82"H x 9.8"D, 45.2 Lbs., Certifications: UL 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 7kW 8.4kW 600VDC 100-500VDC
Ginlong Solis 183-1020-101000 Residential grid-tied Photovoltaic (PV) Inverter, NEMA 4X enclosure with natural convection cooling, 7.6kW, (3) MPPT(s) with operational PV range of 100-500VDC (600VDC PV OCV), (1) inputs per MPPT for connection of up to 3 total PV inputs (9.1kW max combined PV input power), 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz input / 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz sinewave output, 97.5% (CEC) efficiency, each inverter: 13.46"W x 28.82"H x 9.8"D, 45.2 Lbs., Certifications: UL 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 7.6kW 9.1kW 600VDC 100-500VDC
Ginlong Solis 183-1020-101100 Residential grid-tied Photovoltaic (PV) Inverter, NEMA 4X enclosure with natural convection cooling, 8kW, (4) MPPT(s) with operational PV range of 100-500VDC (600VDC PV OCV), (1) inputs per MPPT for connection of up to 4 total PV inputs (9.6kW max combined PV input power), 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz input / 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz sinewave output, 97.5% (CEC) efficiency, each inverter: 13.46"W x 28.82"H x 9.8"D, 45.6 Lbs., Certifications: UL 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 8kW 9.6kW 600VDC 100-500VDC
Ginlong Solis 183-1020-101200 Residential grid-tied Photovoltaic (PV) Inverter, NEMA 4X enclosure with natural convection cooling, 8.6kW, (4) MPPT(s) with operational PV range of 100-500VDC (600VDC PV OCV), (1) inputs per MPPT for connection of up to 4 total PV inputs (9.9kW max combined PV input power), 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz input / 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz sinewave output, 97.5% (CEC) efficiency, each inverter: 13.46"W x 28.82"H x 9.8"D, 45.6 Lbs., Certifications: UL 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 8.6kW 9.9kW 600VDC 100-500VDC
Ginlong Solis 183-1020-101300 Residential grid-tied Photovoltaic (PV) Inverter, NEMA 4X enclosure with natural convection cooling, 9kW, (4) MPPT(s) with operational PV range of 100-500VDC (600VDC PV OCV), (1) inputs per MPPT for connection of up to 4 total PV inputs (10.8kW max combined PV input power), 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz input / 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz sinewave output, 97.5% (CEC) efficiency, each inverter: 13.46"W x 28.82"H x 9.8"D, 45.6 Lbs., Certifications: UL 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 9kW 10.8kW 600VDC 100-500VDC
Ginlong Solis 183-1020-101400 Residential grid-tied Photovoltaic (PV) Inverter, NEMA 4X enclosure with natural convection cooling, 10kW(240VAC)/9kW(208VAC), (4) MPPT(s) with operational PV range of 100-500VDC (600VDC PV OCV), (1) inputs per MPPT for connection of up to 4 total PV inputs (11.5kW max combined PV input power), 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz input / 120/240VAC or 120/208VAC Split-Phase or Single-Phase 60Hz sinewave output, 97.5% (CEC) efficiency, each inverter: 13.46"W x 28.82"H x 9.8"D, 45.6 Lbs., Certifications: UL 1741, UL 1741 SA, Rule 21 Phase I and II compliant (ready for Phase III), UL 1998, UL 1699B, IEEE 1547, FCC Part 15 (Class A & B), CAN/CSA C22.2 107.1-1 10kW(240VAC)/9kW(208VAC) 11.5kW 600VDC 100-500VDC