Connect With Us

Contact Us Today For Support - 954.903.4040

Choose your Solution

400VAC 3-Phase Hybrid Virtual Synchronous Generators (VSG)
(text)

Text

Mfc SourceID Description AC System Voltage
Sinexcel 184-1040-100100 30kVA Rack Mountable bi-directional grid-interactive/off-grid energy storage inverter, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), IP20/NEMA 1 with forced air cooling, battery operational range between 200VDC to 750VDC (de-rated AC output for battery voltages between 200VDC to 350VDC), 400VAC 3 phase 50Hz input/output [Non-Isolated (requires separate output isolation XFMR for single phase loads)], 96.5% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 17.32"W x 6.81"H x 23.46"D, 94.8 Lbs., Certifications: IEC62477-1:2012, EN62477-1:2012+A11, IEC62040-1-1: 2002, EN62040-1-1:2003, EN61000-6-2:2005, EN61000-6-4:2007+A1, AS/NZS 4777.2:2015, AS 62040.1.1-2003, VDE-AR-N 4105/08.11, E DIN VDE V 0124-100/10.13, G59/3-2/09.15 ; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1040-100200 30kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, with Utility + PV connection, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (1) PCS-AC-30k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, PV input voltage range between 520 TO 800VDC (MPPT controller based), battery operational range between 250VDC TO 520VDC, 400VAC 3 phase 50Hz or 60Hz input/output [Isolated (built in XFMR)], 0.955 efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 23.62"W x 62.99"H x 23.62"D, 881.8 Lbs., Certifications: see specification sheet for certifications 400VAC
Sinexcel 184-1050-100100 50kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, with Utility + PV connection, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (1) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, PV input voltage range between 520 TO 800VDC (MPPT controller based), battery operational range between 250VDC TO 520VDC, 400VAC 3 phase 50Hz or 60Hz input/output [Isolated (built in XFMR)], 95.5% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 31.5"W x 85.04"H x 31.5"D, 1146.4 Lbs., Certifications: CE LVD, IEC 62477, CE EMC, IEC 61000, AS61000, VDE 4105, AS4777; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1050-100200 100kVA rated (complete power system frame only with no power modules) Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch screen control, with Utility + PV connection, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (0) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, PV input voltage range between 520 TO 800VDC (MPPT controller based), battery operational range between 250VDC TO 520VDC, 400VAC 3 phase 50Hz or 60Hz input/output [Isolated (built in XFMR)], 95.5% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 31.5"W x 85.04"H x 31.5"D, 0 Lbs., Certifications: CE LVD, IEC 62477, CE EMC, IEC 61000, AS61000, VDE 4105, AS4777; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1050-100300 50kVA (expandable to 100kVA within same cabinet) Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch screen control, with Utility + PV connection, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (1) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, PV input voltage range between 520 TO 800VDC (MPPT controller based), battery operational range between 250VDC TO 520VDC, 400VAC 3 phase 50Hz or 60Hz input/output [Isolated (built in XFMR)], 95.5% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 31.5"W x 85.04"H x 31.5"D, 0 Lbs., Certifications: CE LVD, IEC 62477, CE EMC, IEC 61000, AS61000, VDE 4105, AS4777; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1050-100400 100kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch screen control, with Utility + PV connection, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (2) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, PV input voltage range between 520 TO 800VDC (MPPT controller based), battery operational range between 250VDC TO 520VDC, 400VAC 3 phase 50Hz or 60Hz input/output [Isolated (built in XFMR)], 95.5% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 31.5"W x 85.04"H x 31.5"D, 1653.5 Lbs., Certifications: CE LVD, IEC 62477, CE EMC, IEC 61000, AS61000, VDE 4105, AS4777; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-100100 50kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (1) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 94% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 31.5"W x 85.04"H x 31.5"D, 1025.1 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-100200 100kVA rated (complete Power System Frame only with no power modules) Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (2) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 94% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 31.5"W x 85.04"H x 31.5"D, 1300.7 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-100300 50kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (2) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 94% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 31.5"W x 85.04"H x 31.5"D, 1399.9 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-100400 100kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (2) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 94% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 31.5"W x 85.04"H x 31.5"D, 1499.1 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-100500 150kVA rated (complete Power System Frame only with no power modules) Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (3) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 94.5% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 31.5"W x 85.04"H x 31.5"D, 1708.6 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-100600 50kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (3) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 94.5% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 31.5"W x 85.04"H x 31.5"D, 1807.8 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-100700 100kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (3) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 94.5% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 31.5"W x 85.04"H x 31.5"D, 1907 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-100800 150kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (3) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 94.5% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 31.5"W x 85.04"H x 31.5"D, 2006.2 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-100900 250kVA rated (complete Power System Frame only with no power modules) Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, expandable in 50kVA increments with installable rack mount modules up to 250kVA,compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (4) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 95% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 47.24"W x 85.04"H x 31.5"D, 2325.9 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-101000 50kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, expandable in 50kVA increments with installable rack mount modules up to 250kVA,compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (4) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 95% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 47.24"W x 85.04"H x 31.5"D, 2425.1 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-101100 100kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, expandable in 50kVA increments with installable rack mount modules up to 250kVA,compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (4) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 95% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 47.24"W x 85.04"H x 31.5"D, 2524.3 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-101200 150kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, expandable in 50kVA increments with installable rack mount modules up to 250kVA,compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (4) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 95% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 47.24"W x 85.04"H x 31.5"D, 2623.5 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-101300 200kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, expandable in 50kVA increments with installable rack mount modules up to 250kVA,compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (4) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 95% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 47.24"W x 85.04"H x 31.5"D, 2722.7 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-101400 250kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (5) PCS-AC-50k power conversion modules and built in transformer for 3-phase 4-wire applications, IP20/NEMA 1 with forced air cooling, battery operational range between 500VDC to 850VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 95% (CEC) efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 47.24"W x 85.04"H x 31.5"D, 2821.9 Lbs., Certifications: ETL listed conforming to UL1741/UL1741SA, UL9540, CPUC RULE 21, IEEE1547, HECO RULE14H, CEC, CSA22.2, HECO CGS, HECO CSS; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1060-101500 50kW AC to DC / DC to AC power conversion module for use with PWS1-50k through PWS1-250k series bi-directional energy storage inverters, IP20/NEMA 1 with forced air cooling,    input /    sinewave output,  efficiency, overload ratings of , each inverter: "W x "H x "D,  Lbs., Certifications: 400VAC
Sinexcel 184-1070-100100 500kVA rated (complete Power System Frame only with no power modules) Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, expandable in 62.5kVA increments with installable rack mount modules up to 500kVA, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (1) PCS-AC-62.5k power conversion module, 3-phase 3-wire (external transformer required and not included for 4-wire/nuetral wiring applications), IP20/NEMA 1 with forced air cooling, battery operational range between 600VDC to 900VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 98.2% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 43.31"W x 78.74"H x 31.5"D, 529.1 Lbs., Certifications: CE LVD IEC 62477, CE EMC IEC 61000, G59; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1070-100200 62.5kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, expandable in 62.5kVA increments with installable rack mount modules up to 500kVA, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (1) PCS-AC-62.5k power conversion module, 3-phase 3-wire (external transformer required and not included for 4-wire/nuetral wiring applications), IP20/NEMA 1 with forced air cooling, battery operational range between 600VDC to 900VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 98.2% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 43.31"W x 78.74"H x 31.5"D, 628.3 Lbs., Certifications: CE LVD IEC 62477, CE EMC IEC 61000, G59; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1070-100300 125kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, expandable in 62.5kVA increments with installable rack mount modules up to 500kVA, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (2) PCS-AC-62.5k power conversion modules, 3-phase 3-wire (external transformer required and not included for 4-wire/nuetral wiring applications), IP20/NEMA 1 with forced air cooling, battery operational range between 600VDC to 900VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 98.2% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 43.31"W x 78.74"H x 31.5"D, 727.5 Lbs., Certifications: CE LVD IEC 62477, CE EMC IEC 61000, G59; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1070-100400 187.5kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, expandable in 62.5kVA increments with installable rack mount modules up to 500kVA, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (3) PCS-AC-62.5k power conversion modules, 3-phase 3-wire (external transformer required and not included for 4-wire/nuetral wiring applications), IP20/NEMA 1 with forced air cooling, battery operational range between 600VDC to 900VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 98.2% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 43.31"W x 78.74"H x 31.5"D, 826.7 Lbs., Certifications: CE LVD IEC 62477, CE EMC IEC 61000, G59; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1070-100500 250kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, expandable in 62.5kVA increments with installable rack mount modules up to 500kVA, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (4) PCS-AC-62.5k power conversion modules, 3-phase 3-wire (external transformer required and not included for 4-wire/nuetral wiring applications), IP20/NEMA 1 with forced air cooling, battery operational range between 600VDC to 900VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 98.2% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 43.31"W x 78.74"H x 31.5"D, 925.9 Lbs., Certifications: CE LVD IEC 62477, CE EMC IEC 61000, G59; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1070-100600 312.5kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, expandable in 62.5kVA increments with installable rack mount modules up to 500kVA, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (5) PCS-AC-62.5k power conversion modules, 3-phase 3-wire (external transformer required and not included for 4-wire/nuetral wiring applications), IP20/NEMA 1 with forced air cooling, battery operational range between 600VDC to 900VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 98.2% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 43.31"W x 78.74"H x 31.5"D, 1025.1 Lbs., Certifications: CE LVD IEC 62477, CE EMC IEC 61000, G59; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1070-100700 375kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, expandable in 62.5kVA increments with installable rack mount modules up to 500kVA, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (6) PCS-AC-62.5k power conversion modules, 3-phase 3-wire (external transformer required and not included for 4-wire/nuetral wiring applications), IP20/NEMA 1 with forced air cooling, battery operational range between 600VDC to 900VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 98.2% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 43.31"W x 78.74"H x 31.5"D, 1124.4 Lbs., Certifications: CE LVD IEC 62477, CE EMC IEC 61000, G59; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1070-100800 437.5kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, expandable in 62.5kVA increments with installable rack mount modules up to 500kVA, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (7) PCS-AC-62.5k power conversion modules, 3-phase 3-wire (external transformer required and not included for 4-wire/nuetral wiring applications), IP20/NEMA 1 with forced air cooling, battery operational range between 600VDC to 900VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 98.2% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 43.31"W x 78.74"H x 31.5"D, 1223.6 Lbs., Certifications: CE LVD IEC 62477, CE EMC IEC 61000, G59; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1070-100900 500kVA Modular bi-directional grid-interactive/off-grid energy storage inverter with local touch-screen control, compatible with engine-generator based off-grid systems (virtual synchronous generator - VSG), equipped with (8) PCS-AC-62.5k power conversion modules, 3-phase 3-wire (external transformer required and not included for 4-wire/nuetral wiring applications), IP20/NEMA 1 with forced air cooling, battery operational range between 600VDC to 900VDC, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 98.2% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 43.31"W x 78.74"H x 31.5"D, 1322.8 Lbs., Certifications: CE LVD IEC 62477, CE EMC IEC 61000, G59; Protection: OTP, AC OVP/UVP, OFP/UFP, EPO, AC Phase Reverse, Fan/Relay Failure, OLP, GFDI, Anti-islanding 400VAC
Sinexcel 184-1070-101000 62.5kVA AC to DC / DC to AC power conversion module for use with PWS1-500k series bi-directional energy storage inverters, IP20/NEMA 1 with forced air cooling, 400VAC 3 phase 50Hz or 60Hz input / 400VAC 3 phase 50Hz or 60Hz sinewave output, 98.2% efficiency, overload ratings of 105 to 115% = 10min; 115 to 125% = 1min; 125 to 150% = 200ms, each inverter: 19.02"W x 8.66"H x 23.62"D, 99.2 Lbs., Certifications: 400VAC

Text

Text

Features

Traditional

Subtitle 2

Component