Connect With Us

Contact Us Today For Support - 954.903.4040

Choose your Solution

400 VAC Three Phase Critical Power Conversion Systems and Power Module Selection

Application Suggestion: Contact us to evaluate the overall features desired that must be inherent to the tailored system. This will influence the optimum power module to be chosen. Choosing the best module to base the system on WILL ALWAYS BE NECESSARY for these systems. Module choice rests on scalability, energy density, AC and DC operating voltages (battery choice), and features.

 

Mfc SourceID Description Power Range DC Voltage Link
CE+T 189-1020-100100 TSI Bravo - 24/230, Power Conversion Inverter Module, DC input range = 19 to 35vdc, AC input range = 150 to 265VAC with datacenter grade output of 230VAC (measured L-N), 1.5kVA/1.2kW module rating with max parallel ability up to 48kVA/38.4kW. 1.2 to 38.4kW 24
CE+T 189-1010-100100 Bravo 10 - 48/230, Power Conversion Inverter Module, DC input range = 40 to 60vdc, AC input range = 150 to 265VAC with datacenter grade output of 230VAC (measured L-N), 1.25kVA/1kW module rating with max parallel ability up to 40kVA/32kW. 1 to 32kW 48
CE+T 189-1050-100100 TSI Media - 48/230, Power Conversion Inverter Module, DC input range = 40 to 60vdc, AC input range = 150 to 265VAC with datacenter grade output of 230VAC (measured L-N), 1.5kVA/1.2kW module rating with max parallel ability up to 48kVA/38.4kW. 1.2 to 38.4kW 48
CE+T 189-1020-100600 TSI Bravo - 48/230, Power Conversion Inverter Module, DC input range = 40 to 60vdc, AC input range = 150 to 265VAC with datacenter grade output of 230VAC (measured L-N), 2.5kVA/2kW module rating with max parallel ability up to 80kVA/64kW per system cabinet 2 to 64kW 48
CE+T 189-1080-100100 Flexa 25 - 230/230-1, Power Conversion Inverter Module, DC input range = 40 to 60vdc, AC input range = 150 to 265VAC with datacenter grade output of 230VAC (measured L-N), 3kVA/2.4kW module rating with max parallel ability up to 9.6kVA/7.68kW per system cabinet 2.4 to 9.6kW 48
CE+T 189-1010-100200 Bravo ECI - 48/230, Power Conversion Inverter Module, DC input range = 40 to 60vdc, AC input range = 150 to 265VAC with datacenter grade output of 230VAC (measured L-N), 3kVA/2.4kW module rating with max parallel ability up to 2700kVA/2160kW. 2.4kW to 2.16GW 48
CE+T 189-1030-100100 TSI Nova - 48/230, Power Conversion Inverter Module, DC input range = 40 to 60vdc, AC input range = 150 to 265VAC with datacenter grade output of 230VAC (measured L-N), 0.75kVA/0.525kW module rating with max parallel ability up to 24kVA/16.8kW. 525W to 16.8kW 48
CE+T 189-1020-100200 TSI Bravo - 60/230, Power Conversion Inverter Module, DC input range = 48 to 72vdc, AC input range = 150 to 265VAC with datacenter grade output of 230VAC (measured L-N), 2.5kVA/2kW module rating with max parallel ability up to 80kVA/64kW. 2 to 64kW 60
CE+T 189-1020-100300 TSI Bravo - 110/230, Power Conversion Inverter Module, DC input range = 90 to 160vdc, AC input range = 150 to 265VAC with datacenter grade output of 230VAC (measured L-N), 2.5kVA/2kW module rating with max parallel ability up to 80kVA/64kW per system cabinet 2 to 64kW 120
CE+T 189-1020-100500 TSI Bravo - 220/230, Power Conversion Inverter Module, DC input range = 170 to 300vdc, AC input range = 150 to 265VAC with datacenter grade output of 230VAC (measured L-N), 2.5kVA/2kW module rating with max parallel ability up to 80kVA/64kW per system cabinet 2 to 64kW 220
CE+T 189-1010-100500 Bravo ECI - 380/230, Power Conversion Inverter Module, DC input range = 200 to 400vdc, AC input range = 108 to 290VAC with datacenter grade output of 230VAC (measured L-N), 3kVA/2.5kW module rating with max parallel ability up to 450kVA/375kW. 2.5 to 375kW 380
CE+T 189-1010-100800 Bravo ECI - 400/230, Power Conversion Inverter Module, DC input range = 200 to 430vdc, AC input range = 150 to 290VAC with datacenter grade output of 230VAC (measured L-N), 3kVA/2.5kW module rating with max parallel ability up to 450kVA/375kW. 2.5 to 375kW 400
CE+T 189-1090-100100 Flexa 200 - 400/230, Power Conversion Inverter Module, DC input range = 336 to 490vdc, AC input range = 150 to 275VAC with datacenter grade output of 230VAC (measured L-N), 20kVA/20kW module rating with max parallel ability up to 100kVA/100kW. 20 to 100kW 400
CE+T 189-1090-100200 Flexa 200 - 400/400, Power Conversion Inverter Module, DC input range = 336 to 490vdc, AC input range = 150 to 275VAC with datacenter grade output of 400VAC (measured L-N), 20kVA/20kW module rating with max parallel ability up to 100kVA/100kW. 20 to 100kW 400
CE+T 189-1090-100300 Flexa 200 - 400/, Flexa SBP, DC input range = 336 to 490vdc, AC input range = 150 to 275VAC with datacenter grade output of 400VAC (measured L-N), 20kVA/20kW module rating with max parallel ability up to 100kVA/100kW. 20 to 100kW 400
CE+T 189-1090-100400 Flexa 200 - 400/, Flexa 200 - 400/400 w/Flexa SBP, DC input range = 336 to 490vdc, AC input range = 150 to 275VAC with datacenter grade output of 400VAC (measured L-N), 20kVA/20kW module rating with max parallel ability up to 100kVA/100kW. 20 to 100kW 400