Connect With Us

Contact Us Today For Support - 954.903.4040

Choose your Solution

RML090/15X
Modular 208V 3-Phase UPS

ModelNo Description
RML090/15X-0 RML Series modular on-line/double-conversion UPS System cabinet (hot swappable power modules & batteries not included), expandable in same cabinet system by 15kVA increments to 90kVA/90kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection, 23.62"W x 62.99"H x 43.31"D, 363.8 Lbs. (weight without power modules or batteries)
RML090/15X-15 15kVA/15kW RML Series modular on-line/double-conversion UPS System. includes (1) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 90kVA/90kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 62.99"H x 43.31"D, 434.3 Lbs.
RML090/15X-30 30kVA/30kW RML Series modular on-line/double-conversion UPS System. includes (2) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 90kVA/90kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 62.99"H x 43.31"D, 504.9 Lbs.
RML090/15X-45 45kVA/45kW RML Series modular on-line/double-conversion UPS System. includes (3) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 90kVA/90kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 62.99"H x 43.31"D, 575.4 Lbs.
RML090/15X-60 60kVA/60kW RML Series modular on-line/double-conversion UPS System. includes (4) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 90kVA/90kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 62.99"H x 43.31"D, 646 Lbs.
RML090/15X-75 75kVA/75kW RML Series modular on-line/double-conversion UPS System. includes (5) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 90kVA/90kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 62.99"H x 43.31"D, 716.5 Lbs.
RML090/15X-90 90kVA/90kW RML Series modular on-line/double-conversion UPS System. includes (6) 15kVA hot swappable power module(s) to fully populate all power shelves in its’ expandable 15kVA increments to 90kVA/90kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 62.99"H x 43.31"D, 787.1 Lbs.

PML15X
Systems Based on the PML15X power module

15kVA/15kW Power Module used with RML Series modular hot swappable on-line/double-conversion UPS Systems. 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection, 18.11"W x 5.28"H x 31.1"D, 70.5 Lbs.

System Options

Text


Traditional UPS Systems

Tp

Component Selected UPS Systems

Component