ModelNo Description
RML300/15X-0 RML Series modular on-line/double-conversion UPS System cabinet (hot swappable power modules & batteries not included), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection, 78.74"W x 78.74"H x 41.34"D, 1455.1 Lbs. (weight without power modules or batteries)
RML300/15X-15 15kVA/15kW RML Series modular on-line/double-conversion UPS System. includes (1) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 1525.6 Lbs.
RML300/15X-30 30kVA/30kW RML Series modular on-line/double-conversion UPS System. includes (2) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 1596.1 Lbs.
RML300/15X-45 45kVA/45kW RML Series modular on-line/double-conversion UPS System. includes (3) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 1666.7 Lbs.
RML300/15X-60 60kVA/60kW RML Series modular on-line/double-conversion UPS System. includes (4) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 1737.2 Lbs.
RML300/15X-75 75kVA/75kW RML Series modular on-line/double-conversion UPS System. includes (5) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 1807.8 Lbs.
RML300/15X-90 90kVA/90kW RML Series modular on-line/double-conversion UPS System. includes (6) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 1878.3 Lbs.
RML300/15X-105 105kVA/105kW RML Series modular on-line/double-conversion UPS System. includes (7) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 1948.9 Lbs.
RML300/15X-120 120kVA/120kW RML Series modular on-line/double-conversion UPS System. includes (8) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 2019.4 Lbs.
RML300/15X-135 135kVA/135kW RML Series modular on-line/double-conversion UPS System. includes (9) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 2090 Lbs.
RML300/15X-150 150kVA/150kW RML Series modular on-line/double-conversion UPS System. includes (10) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 2160.5 Lbs.
RML300/15X-165 165kVA/165kW RML Series modular on-line/double-conversion UPS System. includes (11) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 2231.1 Lbs.
RML300/15X-180 180kVA/180kW RML Series modular on-line/double-conversion UPS System. includes (12) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 2301.6 Lbs.
RML300/15X-195 195kVA/195kW RML Series modular on-line/double-conversion UPS System. includes (13) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 2372.2 Lbs.
RML300/15X-210 210kVA/210kW RML Series modular on-line/double-conversion UPS System. includes (14) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 2442.7 Lbs.
RML300/15X-225 225kVA/225kW RML Series modular on-line/double-conversion UPS System. includes (15) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 2513.3 Lbs.
RML300/15X-240 240kVA/240kW RML Series modular on-line/double-conversion UPS System. includes (16) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 2583.8 Lbs.
RML300/15X-255 255kVA/255kW RML Series modular on-line/double-conversion UPS System. includes (17) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 2654.4 Lbs.
RML300/15X-270 270kVA/270kW RML Series modular on-line/double-conversion UPS System. includes (18) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 2724.9 Lbs.
RML300/15X-285 285kVA/285kW RML Series modular on-line/double-conversion UPS System. includes (19) 15kVA hot swappable power module(s), expandable in same cabinet system by 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 2795.5 Lbs.
RML300/15X-300 300kVA/300kW RML Series modular on-line/double-conversion UPS System. includes (20) 15kVA hot swappable power module(s) to fully populate all power shelves in its’ expandable 15kVA increments to 300kVA/300kW, 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 78.74"W x 78.74"H x 41.34"D, 2866 Lbs.

PML15X
Systems Based on the PML15X power module

15kVA/15kW Power Module used with RML Series modular hot swappable on-line/double-conversion UPS Systems. 3 phase 200/208/220VAC 60Hz or 50Hz input/output, Efficiencies = 93% (AC mode), 98% (ECO mode), 93% (Battery mode), 240vdc nominal DCV link for battery connection, 18.11"W x 5.28"H x 31.1"D, 70.5 Lbs.