Connect With Us

Contact Us Today For Support - 954.903.4040

Choose your Solution

RM200/20
Modular Redundant UPS Systems

ModelNo Description
RM200/20-0 (380/400/415) RM Series modular on-line/double-conversion UPS System cabinet (hot swappable power modules & batteries not included), expandable in same cabinet system by 20kVA increments to 200kVA/180kW, 3 phase 380/400/415VAC 50Hz input/output, Efficiencies = 95% (AC mode), 99% (ECO mode), 95% (Battery mode), 480vdc nominal DCV link for battery connection, 23.62"W x 78.74"H x 35.43"D, 394.6 Lbs. (weight without power modules or batteries)
RM200/20-20 (380/400/415) 20kVA/18kW RM Series modular on-line/double-conversion UPS System. includes (1) 20kVA hot swappable power module(s), expandable in same cabinet system by 20kVA increments to 200kVA/180kW, 3 phase 380/400/415VAC 50Hz input/output, Efficiencies = 95% (AC mode), 99% (ECO mode), 95% (Battery mode), 480vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 78.74"H x 35.43"D, 443.1 Lbs.
RM200/20-40 (380/400/415) 40kVA/36kW RM Series modular on-line/double-conversion UPS System. includes (2) 20kVA hot swappable power module(s), expandable in same cabinet system by 20kVA increments to 200kVA/180kW, 3 phase 380/400/415VAC 50Hz input/output, Efficiencies = 95% (AC mode), 99% (ECO mode), 95% (Battery mode), 480vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 78.74"H x 35.43"D, 491.6 Lbs.
RM200/20-60 (380/400/415) 60kVA/54kW RM Series modular on-line/double-conversion UPS System. includes (3) 20kVA hot swappable power module(s), expandable in same cabinet system by 20kVA increments to 200kVA/180kW, 3 phase 380/400/415VAC 50Hz input/output, Efficiencies = 95% (AC mode), 99% (ECO mode), 95% (Battery mode), 480vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 78.74"H x 35.43"D, 540.1 Lbs.
RM200/20-80 (380/400/415) 80kVA/72kW RM Series modular on-line/double-conversion UPS System. includes (4) 20kVA hot swappable power module(s), expandable in same cabinet system by 20kVA increments to 200kVA/180kW, 3 phase 380/400/415VAC 50Hz input/output, Efficiencies = 95% (AC mode), 99% (ECO mode), 95% (Battery mode), 480vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 78.74"H x 35.43"D, 588.6 Lbs.
RM200/20-100 (380/400/415) 100kVA/90kW RM Series modular on-line/double-conversion UPS System. includes (5) 20kVA hot swappable power module(s), expandable in same cabinet system by 20kVA increments to 200kVA/180kW, 3 phase 380/400/415VAC 50Hz input/output, Efficiencies = 95% (AC mode), 99% (ECO mode), 95% (Battery mode), 480vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 78.74"H x 35.43"D, 637.1 Lbs.
RM200/20-120 (380/400/415) 120kVA/108kW RM Series modular on-line/double-conversion UPS System. includes (6) 20kVA hot swappable power module(s), expandable in same cabinet system by 20kVA increments to 200kVA/180kW, 3 phase 380/400/415VAC 50Hz input/output, Efficiencies = 95% (AC mode), 99% (ECO mode), 95% (Battery mode), 480vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 78.74"H x 35.43"D, 685.6 Lbs.
RM200/20-140 (380/400/415) 140kVA/126kW RM Series modular on-line/double-conversion UPS System. includes (7) 20kVA hot swappable power module(s), expandable in same cabinet system by 20kVA increments to 200kVA/180kW, 3 phase 380/400/415VAC 50Hz input/output, Efficiencies = 95% (AC mode), 99% (ECO mode), 95% (Battery mode), 480vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 78.74"H x 35.43"D, 734.1 Lbs.
RM200/20-160 (380/400/415) 160kVA/144kW RM Series modular on-line/double-conversion UPS System. includes (8) 20kVA hot swappable power module(s), expandable in same cabinet system by 20kVA increments to 200kVA/180kW, 3 phase 380/400/415VAC 50Hz input/output, Efficiencies = 95% (AC mode), 99% (ECO mode), 95% (Battery mode), 480vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 78.74"H x 35.43"D, 782.6 Lbs.
RM200/20-180 (380/400/415) 180kVA/162kW RM Series modular on-line/double-conversion UPS System. includes (9) 20kVA hot swappable power module(s), expandable in same cabinet system by 20kVA increments to 200kVA/180kW, 3 phase 380/400/415VAC 50Hz input/output, Efficiencies = 95% (AC mode), 99% (ECO mode), 95% (Battery mode), 480vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 78.74"H x 35.43"D, 831.1 Lbs.
RM200/20-200 (380/400/415) 200kVA/180kW RM Series modular on-line/double-conversion UPS System. includes (10) 20kVA hot swappable power module(s) to fully populate all power shelves in its’ expandable 20kVA increments to 200kVA/180kW, 3 phase 380/400/415VAC 50Hz input/output, Efficiencies = 95% (AC mode), 99% (ECO mode), 95% (Battery mode), 480vdc nominal DCV link for battery connection (battery cabinet & batteries not included), 23.62"W x 78.74"H x 35.43"D, 879.6 Lbs.

PM20 Power Module
Systems Based on the PM20 power module

20kVA/18kW Power Module used with RM Series modular hot swappable on-line/double-conversion UPS Systems. 3 phase 380/400/415VAC 50Hz input/output, Efficiencies = 95% (AC mode), 99% (ECO mode), 95% (Battery mode), 480vdc nominal DCV link for battery connection, 17.32"W x 5.28"H x 23.23"D, 48.5 Lbs.

System Options

Text

Traditional UPS Systems

Tp

Component Selected UPS Systems

Component