EnerSys GT Series lead-acid flooded Telecom Central Office batteries

Model NumberSpecified Power Item IDMfc AvailabilityBattery or Battery System extended description
2GT-9103-1210-102000Current manufacture offeringTelecom / Central Office – Long Rate Multi-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 4V with (4) Cast Lead Post terminals [928Ah (c8), 1.215 S.G.], 12.4″L x 15.1″W x 27.3″H (max ht), 367 Lbs
2GT-11103-1210-102100Current manufacture offeringTelecom / Central Office – Long Rate Multi-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 4V with (4) Cast Lead Post terminals [1080Ah (c8), 1.215 S.G.], 12.4″L x 15.1″W x 27.3″H (max ht), 402 Lbs
2GT-13103-1210-102200Current manufacture offeringTelecom / Central Office – Long Rate Multi-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 4V with (4) Cast Lead Post terminals [1216Ah (c8), 1.215 S.G.], 12.4″L x 15.1″W x 27.3″H (max ht), 436 Lbs
GT-15103-1210-102300Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [1680Ah (c8), 1.215 S.G.], 12.4″L x 15.1″W x 27.3″H (max ht), 347 Lbs
GT-17103-1210-102400Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [1800Ah (c8), 1.215 S.G.], 12.4″L x 15.1″W x 27.3″H (max ht), 364 Lbs
GT-19103-1210-102500Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [1960Ah (c8), 1.215 S.G.], 12.4″L x 15.1″W x 27.3″H (max ht), 382 Lbs
GT-21103-1210-102600Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [2112Ah (c8), 1.215 S.G.], 12.4″L x 15.1″W x 27.3″H (max ht), 401 Lbs
GT-23103-1210-102700Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [2544Ah (c8), 1.215 S.G.], 15.1″L x 16.6″W x 27.3″H (max ht), 483 Lbs
GT-25103-1210-102800Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [2720Ah (c8), 1.215 S.G.], 15.1″L x 16.6″W x 27.3″H (max ht), 501 Lbs
GT-27103-1210-102900Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [2880Ah (c8), 1.215 S.G.], 15.1″L x 16.6″W x 27.3″H (max ht), 520 Lbs
GT-29103-1210-103000Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [3032Ah (c8), 1.215 S.G.], 15.1″L x 16.6″W x 27.3″H (max ht), 538 Lbs
GT-31103-1210-103100Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [3176Ah (c8), 1.215 S.G.], 15.1″L x 16.6″W x 27.3″H (max ht), 557 Lbs
GT-33103-1210-103200Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [3296Ah (c8), 1.215 S.G.], 15.1″L x 16.6″W x 27.3″H (max ht), 583 Lbs
GT-35103-1210-103300Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [3432Ah (c8), 1.215 S.G.], 15.1″L x 16.6″W x 27.3″H (max ht), 601 Lbs
GT-37103-1210-103400Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [3544Ah (c8), 1.215 S.G.], 15.1″L x 16.6″W x 27.3″H (max ht), 620 Lbs
GT-39103-1210-103500Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [3648Ah (c8), 1.215 S.G.], 15.1″L x 16.6″W x 27.3″H (max ht), 638 Lbs
GT-41103-1210-103600Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [3728Ah (c8), 1.215 S.G.], 15.1″L x 16.6″W x 27.3″H (max ht), 657 Lbs
GT-43103-1210-103700Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [3824Ah (c8), 1.215 S.G.], 15.1″L x 16.6″W x 27.3″H (max ht), 675 Lbs
GT-45103-1210-103800Current manufacture offeringTelecom / Central Office – Long Rate Single-Cell Flooded Lead-Acid Battery, Lead Antimony Flat Plate, Polycarbonate case, 2V with (4) Cast Lead Post terminals [3896Ah (c8), 1.215 S.G.], 15.1″L x 16.6″W x 27.3″H (max ht), 693 Lbs